RTS Fix List RTS 4 Instrument ON - zero out 5 Instrument OFF - zero out 34 DPI OI - rethink 37 Motor OI #1 replace /icsqstr priority=0, nseq=0 with /icsqpaus command 38 Motor OI #2 add /AGTACQSEQ DISABLE prior to /AFINESUNPT DISABLE 40 Telescope High Temperature replace /icsqstr priority=0, nseq=0 with /icsqpaus command 45 Why are there two no-op commands, /SWNOOP, commands in this RTS? Are they placeholders for commands thay never were added? 46 Quadrant selector high temp replace /icsqstr priority=0, nseq=0 with /icsqpaus command This RTS has a no-op commands as well - why? 47 Camera electronics high temp replace /icsqstr priority=0, nseq=0 with /icsqpaus command 49 CC aliveness failure response Should /icsqpaus be added to stop sequences? 52 Instrument ON continued - zero out 53 Instrument ON continued - zero out 54 Take a Picture - zero out Action Points 17 DPU Over Current Should we extend this one in number of samples to be 50 (like the Motor OI) to account for long focus moves? 21 NOTE: We should not have had to disable this action point during sequence runs because the number of samples had been raised to 50, accounting for full range of focus moves The following Action Points have sample rates much lower than intended, however it may not be needed to change to the original 2 minutes 24 Current samples = 24 (24 sec); change to 120 Anomalies Why did the icsqstr pri=0 stop a priority 1 sequence?